| Specification |
|
Temperature [°C (°F)]
|
Resistance (kΩ)
|
| -40 (-40) | 0.17 |
| 0 (-32) | 0.201 |
| 100 (212) | 0.276 |
| 200 (392) | 0.35 |
| 300 (572) | 0.42 |
| 400 (752) | 0.489 |
| 500 (932) | 0.555 |
| 600 (1112) | 0.618 |
| 700 (1292) | 0.68 |
| 800 (1472) | 0.739 |
| 850 (1562) | 0.767 |
| Description |
| Circuit Diagram |




| Inspection |
| 1. | Turn ignition switch OFF. |
| 2. | Disconnect the connector of exhaust gas temperature sensors #1/#2. |
| 3. | Measure resistance between sensor signal terminal and ground terminal. |
| 4. | Check that the resistance is within the specification. Exhaust Gas Temperature Sensor [EGTS #1, #2 (T3, T4)]
|
| Removal & Installation |
| 1. | Turn the ignition switch OFF and disconnect the battery negative (-) terminal. |
| 2. | Disconnect the EGTS connector (A). |
| 3. | Remove the EGTS (B).
|
| 4. | Install the sensor in the reverse order of removal.
|
| 1. | Turn the ignition switch OFF and disconnect the battery negative (-) terminal. |
| 2. | Disconnect the EGTS connector (A).
|
| 3. | Remove the EGTS (A).
|
| 4. | Install the sensor in the reverse order of removal.
|
Specifications Specification HO2S [Bank 1/Sensor 1] Item Specification Heater Resistance (Ω) 2.
Specifications Specification Item Specification Rated Voltage (V) 5 Operating Voltage (V) 4.
Components and components location Components 1. Door lock/unlock knob cable 2. Door inside handle cable 3. Door latch assembly Repair procedures Inspection • When removing with a flat-tip screwdriver or remover, wrap protective tape around the tools to prevent damage to
Components and components location Component Location 1. Temerature Control Actuator Description and operation Description 1. Heater unit includes mode control actuator and temperature control actuator. 2. Temperature control actuator is located at the heater unit.