| Removal |
| 1. | Remove the fuel pump.
(Refer to Fuel Delivery System - "Fuel Pump")
|
| 2. | Disconnect the fuel pump motor connector (A) and fuel sender connector (B).
|
| 3. | Disconnect the fuel feed tube quick-connector (A) after removing the fixing clip (B).
|
| 4. | Remove the cushion pipe fixing clip (A), and then separate the head assembly (B) from reservoir cup.
|
| 5. | Press the fixing hook (A) with a driver and then remove fuel sender in the arrow direction.
|
| 6. | Remove the reservoir-cup (B) after releasing the fixing hooks (A).
|
| 7. | Remove the fuel pressure regulator fixing clip (A).
|
| 8. | Remove the fuel pressure regulator (A) from the fuel filter.
|
| Installation |
| 1. | Install in the reverse order of removal. |
Repair procedures Removal 1.Remove the fuel pump. (Refer to Fuel Delivery System - "Fuel Pump") 2.Disconnect the fuel pump motor connector (A) and fuel sender connector (B).
Repair procedures Removal Low Pressure Fuel Line [High pressure fuel pump ↔ Extension fuel line engine room side] 1.Release the residual pressure in fuel line.
Components and components location Components Driver Power Window Switch Connector Pin Information [All Manual / Auto Down Type] (LHD) No. Description No.
Specifications Specification Item Specification Ultrasonic sensor Voltage rating DC 12V Detecting range 11.8 - 39.3 in (30 - 100 cm) Operation voltage DC 9 - 16 V Operation current 60mA Max.